COATING THICKESS METER
Type : BB25Negara Asal : Germany
Specification
Benefits in practice:
- Dual sensor for measuring the thickness of non-magnetic layers on each magnetic and non - magnetic metals
- Wide measuring range from 0 to 2,000 µm
- Error indicator incorrect measurement
- Simple zero -point calibration for rapid deployment and high precision
- Memory for up to 2,500 measurements
- All memory values and groups directly stored in the unit
- Bluetooth interface for PC data transfer
- Simple one-handed operation
- The light adjustable backlight
- Automatic switch off
Technical details:
- Sensor: Ferromagnetic Substrates
- Operating principle: magnetic induction
- Guaranteed tolerance: 0 ~ 1000 µm (± 2 % ±2 µm); 1000 ~ 2000 µm (± 3.5 %)
- Bending radius minimum: (Surface) 1.5 mm
- Minimum measured surface: Ø 7 mm
- Critical base layer thickness: 0.5 μm
- Measuring range: 0 bis 2,000 μm
- Accuracy: 0 ~ 100 µm (0.1 µm); 100 ~ 1000 µm (1 µm); 1000 ~ 2000 µm (0.01 mm)
- Sensor: NE-metallic substrates
- Operating principle: eddy current
- Guaranteed tolerance: 0 ~ 1000 µm (± 2 % ±2 µm); 1000 ~ 2000 µm (± 3.5 %)
- Bending radius minimum: (Surface) 3 mm
- Minimum measured surface: Ø 5 mm
- Critical base layer thickness: 0.3 μm
- Measuring range: 0 bis 2,000 μm
- Accuracy: 0 ~ 100 µm (0.1 µm); 100 ~ 1000 µm (1 µm); 1000 ~ 2000 µm (0.01 mm)
- Functions: error indicator for measurement error, adaptive backlight, auto power off, Bluetooth
- Dimensions: 113,5 x 54 x 27 mm
- Weight: 110 g (incl. batteries)